The correct boot operation process of the DC screen_Chuanyang Electric Co., Ltd.
The correct boot operation process of the DC screen
Date of publication: 2017-12-4
The correct start-up operation process of the DC screen: 1. When the DC screen is turned on, first use the special handle to put the two fuse cores (NT00) into the fuse holder (RT16-00), connect the battery pack to the high-frequency module in the cabinet, and monitor by U04 The panel display window lights up, the monitoring system starts to work, and the system enters the automatic control operation state. 2. Turn on the AC circuit breakers (QF1, QF2) in the DC panel, and introduce the external AC into the DC panel, the display window of the high-frequency module lights up, and the high-frequency switching power supply module starts to work. 3. Turn on the DC feed switch of the lower door of the DC screen. The indicator light is on to indicate that the DC screen starts to provide DC power to the outside, and the boot is completed..Fourth, the specific operation method of the DC screen: 1. Select the normal screen of the DC screen: the operation of the controller can be carried out through the upper computer or the keyboard. For the operation method of the upper computer, please refer to the communication protocol section. This section explains the keyboard operation method. The keyboard is composed of six light touch keys, as shown in the figure below: The “Settings” key is used to enter the menu. In the normal screen state, press this key to enter the first level of the menu. At the same time, it is also the “Exit” button, press this button to exit to the previous menu in the sub-menu state.Press with the “+” key at the same time to reset the controller and restart it. ? “+” key Press the “+” key in the parameter setting state to increase the value.Press and hold to increase continuously. At the same time, it is also the “Equal/Float” button. Press this button to switch the charging mode in the normal screen state of equal charge/float charge..Press this key in the query menu state to display the software version.Press together with the “Settings” button to reset the controller and restart it. ?”-” key Press the “-” key in the parameter setting state to decrease the value.Press and hold to continuously decrease. At the same time, it is also the “query” button, press this button in the normal screen state to enter the query menu. ?”▲” key to move the cursor key up.Used for menu item selection. ?”▼” key to move the cursor down or page up key.Used for menu item selection and screen page turning.In the normal screen state, it can be used to cycle to select the normal screen. ?”Confirm” key When operating the menu, press this key to confirm that the operation is valid.At the same time, it is also a “mute” button. When the system emits a sound alarm, press this button to mute the sound.5. When the system is powered on, the screen will display as shown below: Wait for 28 seconds to enter the initial normal screen, and the screen will display page 2 or 3.. In the normal screen state, according to the system situation, the screen displays one of the following four pages, as follows: Page 1: Page 2: Page 3: Page 4: Press the “▼” key to select the timing page or the voltage and current page.100Ah/110V cabinet type DC screen Source of this article: Baidu Library by Chuanyang Electric Co., Ltd. http://www.chyele.com reprint
DC screen news: