Port State Control Inspections

  

  Details of Detention of Hong Kong Ships

  (1 January 2007 to 31 December 2007)

  No.

  State

  Port

  Detained Date

  Age

  Deficiencies

  Deficiency action code

  TOKYO MOU

  one

  Australia

  Brisbane

  24-Jan-07

  Thirty-one

  1) Many hatch cover securing cleats missing and not operational

  Thirty

  2) Bridge visibility obstructed by 5 high containers loaded in bay 37 & 38

  Thirty

  3) Many containers not secured correctly and in accordance with the

  ships cargo securing manual. [turnbuckle locking nuts not locked,

  Thirty

  numerous locking cone pins not fitting, locking cone seats not seated

  4) X band Radar vey poor display on short ranges

  Seventeen

  5) Many hatch cover security cleats out of adjustment

  Seventeen

  6) Port and stbd sidelights covered by white overspray

  Seventeen

  Two

  Australia

  Bunbury, WA

  16-Mar-07

  Ten

  1) Port and stb E/R vent fire dampers wasted/damaged and inoperable

  Thirty

  three

  Australia

  Dampier

  28-Dec-07

  Twelve

  1) No. 2 E/room Fire Damper – wasted

  Thirty

  2) No. 3 E/room Fire Damper – not operational

  Thirty

  3) Passage plan not berth to berth

  Seventeen

  4) Port liferafts not ready for operation – roped in

  Seventeen

  5) Embarkation ladder not ready for immediate use (fwd ladder)

  Seventeen

  four

  Australia

  Darwin

  10-Jan-07

  Sixteen

  1) Portable foam fire extinguishers defective – no foam produced only water

  Thirty

  2) Goose neck ventilators around deck, seals & closing screws defective on some

  Seventeen

  3) Escape hatch stb’d poop deck, cover securing defective

  Seventeen

  4) Foam tank gauge glass leaking. Tank contents low

  Seventeen

  5) Boiler burner fuel oil leak

  Seventeen

  6) Main engine high pressure fuel pipes not secured at sliding flange. Pipes removed at fuel pumps

  Seventeen

  7) Lights in engine room escape trunk out

  Seventeen

  five

  Australia

  Fremantle

  2-Apr-07

  nine

  1) Radio technical advised that MF/HF radio installation is not operations

  Thirty

  2) Chief officer COR or Evidence of application for cor not sighted

  Seventeen

  3) Radio log book not maintained as per flag state requirements (correct log entries to be made forthwith)

  Seventeen

  4) Passage plan not uptodate, nautical publications not corrected

  Seventeen

  5) Crew to demonstrate HF DSC operation

  Seventeen

  6) Engine control room main switchboard 220 volt with earth fault

  Seventeen

  7) (P) lifeboat emergency light not working

  Seventeen

  8) Forward liferaft means of embarkation (ladder) stored below deck and not readily available

  Seventeen

  9) Rope store aft (p) hatchcoaming edges wasted and hatchcoer not sealing

  Seventeen

  six

  Australia

  Gladstone

  24-Jan-07

  five

  1) Starboard side lifeboat on load release system defective. Indicators showing locked, where as system in open position

  Thirty

  No.

  State

  Port

  Detained Date

  Age

  Deficiencies

  Deficiency action code

  2) Charts AUS 819, 820 old editions onboard

  Seventeen

  3) All mooring winch clutch pins not in use/missing

  Seventeen

  4) enginroom 2nd deck elevator door catch defective. Crew opened door when no elevator present

  Seventeen

  5) Forward liferaft embarkation ladder. No method of securing to ship for use

  Seventeen

  6) Portside lifeboat on load release system incorrectly reset

  Seventeen

  7) IAMSAR Manual latest amendments not onboard

  Fifteen

  8) ITU publication IV old edition onboard

  Fifteen

  seven

  Australia

  Gladstone

  27-Feb-07

  Twenty-four

  1) Air con trunking holded below damper

  Thirty

  2) Liferaft means of manual release inoperable

  Thirty

  3) No 3, 4, 5, 6 Hatch main supports cracked, holed, wasted

  Thirty

  4) Engine room hatch not secured

  Seventeen

  5) Air con inlet, damper not fully closing

  Seventeen

  6) Limit switches lifeboats not cutting off in time

  Seventeen

  7) Bilge air pipe holed, repaired with tape

  Seventeen

  8) Steering flat air pipes & rope hatch unable to secure shut, securing devies missing

  Seventeen

  eight

  Australia

  Gladstone

  15-May-07

  five

  1) SMS fails to comply with mandatory rules & regulations, objective evidence items 1, 2, 3, 4, 5, 7, 8, 13

  Thirty

  2) No cargo log book or recorded drafts per SOLAS VI7.8

  Seventeen

  3) Garbage record book recorded discharges of cat V on 31/5/04 and 27/2/04 inside the nearest land area

  Seventeen

  4) Passage plan not complying SOLAS V R34

  Seventeen

  5) Aus chart 4621 old edition

  Seventeen

  6) AIS indicates vessel underway

  Seventeen

  7) Lifeboats on load release systems seized, reported by authorised technician during annual service.

  Seventeen

  8) Crew unfamiliar with operation of lifeboat emergency steering

  Seventeen

  9) Fwd means of embarkation, means of attachment sized

  Seventeen

  10) Steering room fire door jammed open

  Seventeen

  11) Oil record book not updated to latest MEPC required Jan 2007

  Fifteen

  12) Garbage record book not updated to MEPC 116/51

  Fifteen

  13) Garbage plackards not taking into account nearest land provisions

  Fifteen

  14) Inspection/maintenance of on load release systems inadequate, objective evidence item 13

  Fifteen

  15) SOLAS training manval, no instuctions for item 15

  Fifteen

  nine

  Australia

  Gladstone

  5-Oct-07

  eight

  1) Life saving appliances not ready for immediate use, evidence by items 7, 9, 10, 11, 12, 13

  Thirty

  2) Passage plan not berth to berth or utilising largest scale charts

  Seventeen

  3) Standard compass 35 degress error

  Seventeen

  No.

  State

  Port

  Detained Date

  Age

  Deficiencies

  Deficiency action code

  4) No Navarea X warnings onboard

  Seventeen

  5) Port lifeboat outside indicators for resetting onload release, indicate system not fully locked

  Seventeen

  6) Port lifeboat Internal markings F & A for hook resetting missing, Main control box markings missing

  Seventeen

  7) Liferaft release for cradles seized, cradle hinges rusted

  Seventeen

  8) Port lifebouy not connected to light

  Seventeen

  9) Crew unable to demonstrate operation of lifeboat emergency steering

  Seventeen

  10) Fwd liferaft manual release not per posted instructions

  Seventeen

  11) Fwd liferaft means of embarkation, attachments seized

  Seventeen

  12) Solas training manuals missing crew & officer mess, only one copy onboard

  Seventeen

  13) Lower stern light weather sheild loose

  Seventeen

  14) E/R sounding pipe closers disconnected

  Seventeen

  15) Stability booklet not approved by current classification society

  Fifteen

  16) No records of navigation activity pilot to berth

  Fifteen

  Ten

  Australia

  Gladstone

  10-Dec-07

  Eighteen

  1) E/R Port side fwd fan dampers not closing

  Thirty

  2) C deck E/R fan dampers not closing

  Thirty

  3) Port lifeboat onload release defective

  Thirty

  4) Fire Panel bridge, Battery failure alarm active

  Seventeen

  Eleven

  Australia

  Hay Point

  21-Feb-07

  four

  1) Emergency fire pump no pressure available for immediate use

  Thirty

  2) Fire Dampers (louvers) for engine room fans stbd aft & port fwd seized open

  Thirty

  3) AIS navigational status not correct for port location

  Seventeen

  4) Voyage plan not in accordance with SOLAS Ch V. Reg 34

  Seventeen

  5) Current editions of navigational charts for intented voyage not on board 250, 246 & 818

  Seventeen

  6) Emergency generator room not clearly marked (no IMO symbol)

  Seventeen

  7) Emergency lighting numerous not working around accommodation block

  Seventeen

  8) Several closing flaps seized around accommodation & CO2 room mushroom vent

  Seventeen

  9) Load line & draft marks not clearly visible (stbd)

  Fifteen

  10) Sewage treatment unit with low air poressure

  Fifteen

  11) Pump shutdowns (ESD) stbd bunkering manifold not operational

  Fifteen

  Twelve

  Australia

  Kwinana

  3-Aug-07

  Twelve

  1) MF/HF GMDSS radio unable to operate on emergency source (dc) power

  Thirty

  2) Voyage plan not prepared from berth to berth

  Seventeen

  3) Magnetic compass not clearly readable from bridge steering position

  Seventeen

  4) Enhanced survey report for last special survey not on board

  Fifteen

  5) CO2 room air vent pipe – temporarily repaired. Permanent repairs to complete by next port

  Fifteen

  Thirteen

  Australia

  Melbourne

  18-Dec-07

  six

  1) Port & Stb’d on load released mechanism is defective

  Thirty

  2) Port & Stb’d M.O.B. bridge buoys are not configured for immediate operation

  Seventeen

  3) Daily service fuel tanks in engine room – Quick closing valves are prevented from operation by bridging pieces

  Seventeen

  No.

  State

  Port

  Detained Date

  Age

  Deficiencies

  Deficiency action code

  Fourteen

  Australia

  Newcastle

  20-Jun-07

  Twelve

  1) MF/HF Radio Installation unable to operate on reserve source of power (dc). (Batteries low on charge or defective)

  Thirty

  2) Funnel fire dampers open/shut signs incorrectly marked (indicates closed when dampers are open).

  Seventeen

  3) Port & starboard lifeboat engine starting batteries low in charge. (No. 1 starboard & No. 1 and No. 2 Port batteries).

  Seventeen

  4) Starboard lifeboat engine exhaust pipe ‘holed’ with exhaust fumes leaking into enclosed lifeboat.

  Seventeen

  5) Starboard lifeboat forward painter ‘failed’ to release when release mechanism operated.

  Seventeen

  6) Port & starboard lifeboat davit brake remote release wire sheaves ‘seized’.

  Seventeen

  7) Starboard lifeboat battery charging plug & lead unable to disconnect readily in case of emergency use of lifeboat.

  Seventeen

  8) MF/HF Radio antennae installation in poor condition wasted wire thimbles, wasted securing points, broken feed through insultor.

  Fifteen

  9) VHF, GPS, Inmarsat C and other cables on bridge top deck (Monkey Island). In poor condition, many cables left unsecured.

  Fifteen

  1) Engine room funnel tops door/hatch left in ‘open’ position. Hatch

  Fifteen

  Australia

  Newcastle

  16-Nov-07

  Twenty-five

  cover hinges broken and securing dogs seized. (Cannot be closed from

  Thirty

  outside space)

  2) Inspection covers to funnel fire dampers service space left

  completely off. Effectively bye-passing funnel fire dampers & unable

  Thirty

  to clsoe in the event of fire.

  3) Diesel generators high pressure fuel pipe jacketed piping holed/broken. Many fittings not secured/bolts missing. (numerous)

  Thirty

  4) Water Ballast tank air vents closing device defective. (wasted top sealling surfaces) Numerous.

  Thirty

  5) Fire detection system emergency back-up batteries defective. (low voltage)(4 pieces).

  Seventeen

  6) Numerous engineroom Fire detector heads defective (not operating fire alarm), some detector heads missing.

  Seventeen

  7) Numerous fire hose nozzles ‘seized’.

  Seventeen

  8) Engineroom vents fire retardant mesh missing. (diesel alternators crankcase vents)(6 pieces)

  Seventeen

  9) Numerous lights out in engineroom upper levels and funnel casing, extremely poor lighting.

  Seventeen

  10) Funnel water drain pipe removed allowing water to flow freely into engineroom. Funnel top casing ‘wasted’ around drain pipe.

  Seventeen

  11) Economiser safety valves easing gear ‘seized’ and easing gear operating wirer guide wire sheaves ‘seized’.

  Seventeen

  12) Air conditioning fans compartment – excessive cardboard, timber, and debris. (fire hazard).

  Seventeen

  13) Diesel generators-excessive oil leaks forward of engines.

  Seventeen

  14) Excessive oil leaks on deck on deck in ‘purifier oom’.

  Seventeen

  15) Excessive oil leaks port aft main engine & behind fuel oil pumps.

  Seventeen

  16) Engineroom bilge emergency suction valve ‘seized’.

  Seventeen

  17) Crews and officers change rooms toilets broken. (health hazard).

  Seventeen

  18) Crews and Officers wash basins and showers – no hot water available. Hot water supply defective.

  Seventeen

  No.

  State

  Port

  Detained Date

  Age

  Deficiencies

  Deficiency action code

  19) Engineroom emergency exit fire doow not fully closing and roped ‘open’.

  Seventeen

  20) Numerous steel mooring ropes in a poor condition rusted & lack of lubrication.

  Fifteen

  Sixteen

  Australia

  Useless Loop

  11-Oct-07

  Twenty-three

  1) Engine room fire damper stbd side forward (No. 29) not operational

  Thirty

  2) Lub oil tanks in E/R with gauged self closing cocks

  Seventeen

  3) Navigation light aft, lantern loose affecting the angle of visibility as required by COLREG

  Seventeen

  4) Main deck hatch no. 2 port forward cargo light hatch closing device wasted for 25%

  Fifteen

  5) Crew accommodation shower room with 4 showers: 1 shower missing of shower head and curtest c ; 2 showers draw’s are blocked

  Fifteen

  Paris MOU

  one

  Belgium

  Antwerp

  22-Mar-07

  Twenty-six

  1) Rudder angle indicator – inoperative

  Thirty

  2) Magnetic compass not readable at helsman position

  Thirty

  3) Fire flap funnel not closing properly

  Thirty

  4) PS lifeboat propeller funnel damaged


Posted

in

by

Tags: