In the maintenance and management of DC screens, it is important to promote the application of safety warning cards.!_Chuanyang Electric Co., Ltd.

In the maintenance and management of DC screens, it is important to promote the application of safety warning cards.!_Chuanyang Electric Co., Ltd.
In the maintenance and management of DC screens, it is important to promote the application of safety warning cards.!

Date of publication: 2017-10-24

In HSE management, there is a very practical management tool called security incident experience feedback, that is, the establishment of a “safety warning card” to extensively collect and organize internal and external security incidents in the system, and formulate preventive and pre-control measures to prevent the repetition of similar incidents happen.The “safety warning card” is short and concise, which is convenient for the majority of electricians to read and circulate. It can also be pasted on the wall according to the requirements of the government and enterprise management to warn more electrical workers, and improve workers’ safety awareness in a subtle way..Thanks to the “explosive” development of the Internet and WeChat, thanks to many electrician friends who selflessly shared, we can get many accident cases as soon as possible.When we see an accident case or an accident report, what we see is often a “long story” of thousands of words, in which the essence and spirit are actually just a few words..We can read more repeatedly, “read the book thin and more refined”, and make a warning card according to the accident process, the analysis of the cause of the accident, and the experience feedback (see attached table 1), with pictures and explanations, the so-called “Safety incident experience feedback” and “publication”, can also be used as training materials for publicity and learning, and can also be summarized and bound into a book, read and learn at any time, it is a good training learning card, I hope everyone likes it.The above are some of my personal training and learning experience. Since the “safety warning card” is being promoted and applied, it is inevitable that there will be many deficiencies. I hope you can comment on it..I hope everyone can actively make suggestions and suggestions to make progress and improve together. “Electrician safety is everyone’s responsibility.” I hope that tragedies will not be staged..Safety alert card of a power generation company in Ningxia “8.25” minor personal injury and unit trip accident 1. After the accident, on August 25, 2017, a power plant operator operated a 6kV 1A section power supply inlet switch from the test position to the working position, and a three-phase arc short-circuit fault occurred, causing Two people were injured (about 10% of XX’s arm was burned, Wang XX’s clavicle fractured), the power supply inlet switch of the 1A section of the busbar in the 6kV power distribution room of Unit 1 was burned, and Unit 1 was shut down..2. Analysis of the cause of the accident 1.The vacuum package of the 6kV 1A section busbar working power inlet switch of Unit 1 leaked. During the operation of the 6kV 1A section working power inlet switch from the test position to the working position, the B-phase vacuum bubble breakdown occurred, resulting in a three-phase arc short circuit fault..2.A power plant failed to carry out electrical preventive tests in accordance with industry standards, and failed to discover the major hidden dangers of the switch in time.Three, experience feedback 1.Carry out preventive tests of electrical equipment in strict accordance with industry standards.2.Strictly implement closed-loop rectification of problems raised by technical supervision and inspection.3.Strictly implement safety technical measures, and perform safety protection for operators. No. 1 unit 6kV 1A section busbar working power inlet switch lower contact No. 1 unit 6kV 1A section bus working power inlet switch body

DC screen news:


Posted

in

by

Tags: